commisioner: municipality Amsterdam
projectmanagement: SRO, Amersfoort
architects: Mecanoo, Delft and Wind, Drachten
services consultant: Herman de Groot, Leusden
structural engineering: Pieters Bouwtechniek
building physics: Climatic Design Consult
CDC advised about:
- daylight and luminance control via completely glass bricks walls ;
- sound insulation between sports hall and under the hall situated swimming pool and between fitness accomodation and offices under that acoomodation;
- humidity control in copnstructions of the swimming pool;
- noise emission from swimming pool to surroundings;
- acoustics in swimming pool, sports hall and central hall.